PCB Trace Width Calculator

The TOPFAST PCB Trace Width Calculator helps engineers determine the optimal copper trace width based on current, copper weight, temperature rise, and layer type. Using IPC-2221 guidelines, this tool helps improve power integrity, prevent overheating, and ensure reliable PCB performance.

Input parameters
A
Calculation results
Internal Layers (IPC-2221)
— mil
mil
Ω
V
W
External Layers in Air
— mil
mil
Ω
V
W

* Internal layer results use IPC-2221 internal constants (k=0.024). External layer results use external constants (k=0.048). Resistance and power loss calculations assume copper resistivity of 1.72×10⁻⁸ Ω·m at ambient temperature with temperature coefficient 0.00393/°C.

Formula
Step 1 — Calculate cross-sectional Area (mil²):
A = ( I K × TRiseb ) 1/c
Step 2 — Calculate Trace Width (mil):
W = A t × 1.378

For IPC-2221 internal layers:

k = 0.024,  b = 0.44,  c = 0.725

For IPC-2221 external layers:

k = 0.048,  b = 0.44,  c = 0.725

where k, b, and c are constants resulting from curve fitting to the IPC-2221 curves.

Common values:

Thickness: 1 oz (= 1.378 mil)
Ambient: 25 °C
Temp rise: 10 °C

Resistance formula:
R = ρ × L × [1 + α(T − 20°C)] W × t

ρ = 1.72×10⁻⁸ Ω·m (copper resistivity at 20°C)
α = 0.00393 /°C (temperature coefficient)
T = ambient temperature (°C)
L = trace length, W = width, t = thickness